The power control module controls the onoff of the compressor, and the fans.Fisher Paykel Appliances 5800 Skylab Road Huntington Beach CA 92647 Telephone: 888 936 7872 COPYRIGHT FISHER PAYKEL LTD 2007 - ALL RIGHTS RESERVED.Static Strap To be used as ESD protection when replacing the console board.
Fisher And Paykel Active Smart Fridge Fan Not Working Download Data FromInterface Pen Mk 2 Used to retrieve and download data from the electronic control module along with the diagnostic programme on a laptop.
Cabinet levelling can be done by adjustment of the front roller-levelling wheel fitted ex factory. See diagram 4.1B Weight should be lifted off cabinet for ease of adjustment. CURRENT TYPE Diagram A (Rear Roller) Diagram B (Front Leveller. It is preferable to have the appliance level in appearance where both doors will close with the aid of the door closing components. LINER A one piece vacuum formed ABS liner with a plug-in divider. DIVIDER PARTITION Injected moulding of HIPS, with two outer injected moulded housings, and an insulated ducted moulded polystyrene inner core. FAN MOTORS DC 12 volt brushless variable speed fan motors for air circulation in both 1 x FC and 1 x PC compartments. Defrost Cycle of the Active Smart Refrigerator (With Fin On Tube Evaporator) Compressor Defrost element Defrost element Compressor Both PC FC turns off turns on turns off turns on fans turn on. This tube runs from the compressor compartment forward to the front bottom edge of the cabinet, returning down the left hand side to be connected to the left hand side condenser coil (viewed from the rear of the cabinet). Condensate from the evaporator defrosting drops into a collection trough, which has an outlet hole in the centre of the liner. A tube then allows the condensate to flow into a water evaporation tray above the compressor. One third of the condenser is attached to the back panel, and the other parts are attached to the inside of the right and left sides of the cabinet wrapper (as viewed from the back) all being foamed into place. Fisher And Paykel Active Smart Fridge Fan Not Working Full System DiagramThey should be read in conjunction with the full system diagram (See Diagram 0). Service tube (process pipe) Suction line Discharge line into water evaporator tray. Water evaporator to condenser back panel Back panel to base tube Capillary tube. The purpose of the Power Control module is to turn on the compressor, which cools the evaporator, then to use the fans to efficiently cool the compartments. The typical time interval for defrosts is between 12 hours and 1 day. However it can be as short as 3 hours or as long as 70.8 hours depending on the usage and environment. Thermal Fuse There are two thermal fuses mounted in the wiring harness of the defrost element, having a tripping temperature of 160. They provide the required cooling power to both compartments.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |